If you can still not find the datasheets on these two devices, please let us know. 5cd9. They include a 48-port Gigabit Ethernet Copper Module and 48-port Gigabit Ethernet Fiber Module. 0(1)SY2 Ok. QTY. Canon Perdido, Suite 100 Santa Barbara, CA 93101Same bug for VS-SUP2T-10G on Cisco 6807XL VSS version 15. VS-S2T-10G-XL=. Le centre d’assistance technique de Cisco (TAC) continuera de prendre en charge les clients dont les contrats. Les clients ont jusqu'au 30 octobre 2020 pour commander les produits concernés. (CPU 100%, log %SNMP-SW1-3-INPUT_QFULL_ERR: Packet dropped due to input queue full) Problem resolved with : snmp-server view cutdown iso included snmp-server view cutdown lldpXMedMIB excluded snmp-server community surpass view cutdown RO YYY. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table. 0021 2. Note these both require the High Speed Fan and a 2500 watt power supply. 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles and accessories Milestone Definition Date End-of-Life Announcement Date The date the document that announces the end-of-sale and end-of-life of a product is distributed to the general public. Global Shipping, Global Warranty. DRAM. 1445. can we install new C6800-8P10G= Interface Module during switch power ON (during working condition), or. 136 W. Cisco announces the end-of-sale and end-of life dates for the Cisco Catalyst 6500 Series Supervisor Engine 32, plus the Cisco Catalyst 6500 and Cisco 7600 Series Supervisor Engine 32 Bundles. SY3. Feature VS-S2T-10G VS-S2T-10G-XL Port security Yes Yes IEEE 802. I have WAN connection connected on port on Sup card on each chassis and they are in a port-channel. 0(1)SY3 Ok Mod. Solved: Hello all experts! No matter how I search on the internet about "VS-SUP2T-10G", there was no datasheet. 5(1)SY5. ! And then I found that VS-SUP2T-10G's Factory ID was VS-S2T-10G! But I don't know the difference between them. 0(1)SY7a ) with VS-SUP2T-10G. Download the datasheet of Cisco VS-S2T-10G-XL. I have two 6807 chassis with VSS architecture. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1 of the EoL bulletin. UDI=VS-SUP2T-10G:SALxxxxxxxx there is no service impact and we won't be fixing it for now. 3 CPU Daughterboard VS-F6K-MSFC5 SAL1930KNDW 3. C6880-16P10G. 0 Ok 8 Distributed Forwarding Card C6800-DFC SAL2120011E 1. module 7 device-1 temperature: 40C. 8ad0 to 6073. 44 550. Only a single chassis VSS with single or dual Supervisors is supported. 10. 7 48 CEF720 48 port 10/100/1000mb. 00BOM. W/VS-F6K-PFC4. I am trying to apply queueing configuration on the interface but failed. (Don’t be confused by the fact that the old Supervisor 2 went end-of-sale on 2007. Free shipping. 5G/5G/10G copper options. Price Alert. The scope of delivery corresponds to the product. 98 x 14. Router# show platform hardware capacity system System Resources PFC operating mode: PFC4 Supervisor redundancy mode: administratively sso, operationally sso Switching resources: Module Part number Series CEF mode 6 VS-SUP2T-10G supervisor CEF Router# This example shows how to display VLAN information: 2 8 DCEF2T 8 port 10GE WS-X6908-10G SAL190696FB. Current version is. 10 WS-SUP720 Supervisor Engine 720 with PFC3A daughter card andThis PDN was published on 10/31/2014 and lists all parts with the LTB date of 07/31/2015. Get a closer look at a Catalyst 9600. what is the IOS code running, Try below syntax : logging origin-id string <device_hostname>. 1 6 CPU Daughterboard VS-F6K-MSFC5 2. It supports 80 Gbps with your sup2T. Page 2 of 22 Contents IntroductionEOL13211 - Amended. The front panel is labeled WS-X6708-10GE. Hi All, I am currently looking at a VSS solution, which requires PoE line cards. Cisco OneX Converter Module5 5 Supervisor Engine 2T 10GE w/ CTS (Hot) VS-SUP2T-10G SAL1731APXD 6 5 Supervisor Engine 2T 10GE w/ CTS (CSSO VS-SUP2T-10G SAL1731APZY 8 24 CEF720 24 port 1000mb SFP WS-X6824-SFP SAL1730AFG9. Catalyst 6500 Sup2T; VS-S2T-10G-XL-RF; VS-S2T-10G-XL-RF. However, from the second link I see a limit of 256K IPv4 routes for SUP2T and PFC4, instead SUP2T XL and PFC4 XL can support. 1445. Execute the conversion command, which will reboot the switches. And Cisco proposed the 2 substitutes written above: vs-s2t-10g= and vs-s2t-10g-xl=. WS-C6509-E modules installed are: 1 24 CEF720 24 port 1000mb SFP WS-X6724-SFP . Yes and no. $5,500. Mod Ports Card Type Model Serial No. Global Price in USD. 00 1. Free PDF of Cisco VS-S2T-10G-XL. I recall, the only 67xx card that will not work with a sup2T is the 6708, because it comes with a DFC3 that cannot be replaced (with the DFC4 or a CFC). After I Configured VSS, standby VS. Bias-Free Language. The data sheet does not mention anything about the "ip accounting" command. On the 1st chassis I upgraded we had no problems and so I "borrowed" a known working SUP2T and tried it in that. Conditions: reload. 7 5 Supervisor Engine 2T 10GE w/ CTS (Hot) VS-SUP2T-10G SAL202801YG. I have two 6807 chassis with VSS architecture. 2 Ok. 7/31/2015. Uplink ports (PORT 1 through PORT 5) ·Supervisor Engine 2T has five uplink ports: ·Two 10GBASE-X ports·Three 1000BASE-X ports·Each uplink port has a link LED associated with it. The Cisco® Catalyst® 6500 Supervisor Engine 2T is the newest addition to the family of supervisor engines. Step 2 Click New Deployment to create a new deployment profile. In response to Leo Laohoo. . 7 Centralized Forwarding Card. I reviewed the original boot-up process and I can see that the line card is booting up as "Standby". Sup Engine : VS-SUP-2T-10G. 5/5/10G BASE-T on the downlinks. Be aware that you have to also acquire a DFC4-A or DFC4-AXL which is a daughtercard of the line card. The answer, I believe, is yes. Beginner. The Cisco Catalyst 6509-E supports Cisco Catalyst 6500 Series end-to. Could anybody tell me when the dates of Eol of these two modules are?Software compatibility. Cat 6500 Sup2T with 2x0GbE, 3 x1GbE,MSFC5 PFC4XL 2D barcode. Hi there VSS sups , you cant do seamless going to VSS from standard your going to take hits no matter what way , reason being theres a conversion section where it turns the switches into VSS capable , this causes a reboot , no way around it part ofEnd-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6506-E, Catalyst 6509-E, Catalyst 6509-V-E, Catalyst 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles & Accessories 17-Nov-2022. 6 Tbps in wired switching capacity, with up to 6. EOS & EOL: Select Cisco Catalyst 6500 Series Components-Updated 03/Aug/2005. Operating temperature. The documentation set for this product strives to use bias-free language. *May 27 06:47:53. SW1#sh mod switch 1 Switch Number: 1 Role: Virtual Switch Active ----- ----- Mod Ports Card Type Model --- ----- ----- ----- 1 24 CEF720 24 port 1000mb SFP WS-X6824-SFP 3 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6848-GE-TX 5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G 6 5 Supervisor Engine 2T 10GE w/ CTS (CSSO VS-SUP2T. module 1: module 1 power-output-fail: OK module 1 outlet temperature: 66C module 1 inlet temperature: 51C module 1 asic-13 temperature: 79C module 1 asic-14 temperature: 81C module 1 EARL outlet temperature: 47C module 1 EARL inlet. new#show inventorySupervisor Model VS-SUP2T-10G . Brand new. Catalyst 9600 Chassis and Line Cards with C9600X-SUP-2. 07 44. Tray+Sup720-10G; IP Base ONLY incl. 0 C6807-XL-S2T-BUN Chassis+Fan Tray+ Sup2T+2xPower Supply; IP Services ONLY N/A 39 days No 2 -- 0 -- 1. we have two 6509E which are configured in VSS mode with the following modules in each: 1 48 CEF720 48 port 10/100/1000mb Ethernet. Component. BOM. VS-C6509E-SUP2T. 98 x 14. 1. Offering flexible port-speed configurations, the switch supports 48 ports of 100M/1/2. Previous page. VS-C6509E-S720-10G Catalyst Chassis+Fan. The 6500 has only one supervisor engine so we will obviously need some downtime. 87. CSCto26539. 2+ VSS mode support as shown in the Release Notes. If you are looking for other parts in addition to the VS-SUP2T-10G VS-F6K-PFC4 , then please contact us by. The 6 uplink ports support 40/100G QSFP 28. The Future Is 40 Gigabit Ethernet White Paper (PDF - 2 MB) Virtual Private LAN Service on Cisco Catalyst 6500 Supervisor Engine 2T. This chapter describes how to safely install, remove, and verify the operation of the Ethernet switching modules in the Catalyst 6800 series switches. 2(50r)SYS 15. VS-S720-10G-3C . 0 12. Total views 3. Free PDF of Cisco VS-S2T-10G. It is compatible with Sup2T. ROM: System Bootstrap, Version 12. 3 Release Notes for Cisco IOS Release 15. Cisco Nexus 7000 Series Supervisor2 Module. The CISCO Catalyst VS-SUP2T-10G VS-F6K-PFC4 represents one item of our extensive telecommunications portfolio, which includes products from many of the world’s key OEM’s, including Ericsson, Siemens, Nortel, Nokia and Marconi. wrote: Im facing huge packet loss with only longer distances affected. This card can be acquired and installed by yourself with no problems. Note The 1-Gigabit Ethernet ports and the 10-Gigabit Ethernet ports have the same QoS port architecture (2q4t/1p3q4t) unless you disable the 1-Gigabit Ethernet ports with the platform qos 10g-only global configuration command. Explore our database of over. 206. 50. Community. As the 1G and 2 x 10G ports share the total 20G bandwidth points on the SUP2T, if both 10G ports are used for VSL, the 1G ports can not. Step 3 Ensure that the pre-requisites mentioned in the Before you Begin page are satisfied and then click Begin . 部分Cisco. 0f9c. Either two VS-SUP2T-10G or two VS-SUP2T-10G-XL supervisor engines. Cisco IOS software commands display WS-X6708-10GE with either WS-F6700-DFC3C or WS-F6700-DFC3CXL. 36 A; VS-S2T-10G-XL—10. Additionally, customers have the option to migrate to the Supervisor Engine 720-10G-3C, which supports Virtual Switching System (VSS). com is neither a partner nor an affiliate of Cisco, Huawei and Fortinet. bin. 5(1)SY4, page 51 † New Features in Release 15. 1 12. 75. I need to add a new WS-X6708-10G-3C= module to this same chasis . Catalyst 6807-XL Quad Sup2T VSS Deployment. Beginner Options. generation enterprise. 5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL1825UZQ4 Mod MAC addresses Hw Fw Sw Status 5 503d. Switching Modules. The images may differ slightly from the original and are used for illustration. The total number of entries possible depends on the mix of v4/v6 and. I have this problem too. 5cd9. Working in conjunction with the Catalyst ® 6500-E/6807-XL Supervisor Engine 2T/2TXL (VS-S2T-10G & VS-S2T-10GXL), they can serve different needs on. 442 12748176 4456882 2860 33. Note The 1-Gigabit Ethernet ports and the 10-Gigabit Ethernet ports have the same QoS port architecture (2q4t/1p3q4t) unless you disable the 1-Gigabit Ethernet ports with the platform qos 10g-only global configuration command. Specifications. C6K 8P 10G Ethernet module w/DFC4XL (Trustsec) w/2D Barcode: C6800-8P10G: Catalyst 6800 8 port 10GE with integrated DFC4 – CF-ADAPTER-SP: SP adapter for SUP720 and SUP720-10G: VS-S2T-10G: Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE with MSFC5 PFC4 – MEM-A-MSFC3-1GB: 1GB Memory Upgrade Option: VS-S2T. Configure the boot statement to boot. VS-C6513E-SUP2T5 5 Supervisor Engine 2T 10GE w/ CTS (Active)VS-SUP2T-10G SAL15056BKR. With the 1-Gigabit Ethernet ports disabled, the QoS port architecture of the 10-Gigabit Ethernet ports is 8q4t/1p7q4t. I applied ACL and route-map to redirect traffic on an interface. g SolarWinds NPM, you can look at the CPU and memory history before and after. Installing SUP2T in a 6807-XL chassis boosts backplane speed from 80 Gbps of an E-Chassis up to 220 Gbps, although this is nowhere near the chassis maximum capacity of 880 Gbps. 1(2)SY16—20 February 2020 • Release 15. €5€€€ 5€ Supervisor Engine 2T 10GE w/ CTS (Active)VS-SUP2T-10G€ €€€€ SAL15056BKR Sup2T の場合、Eureka という内部コード名が設定されたレイヤ 2(L2)フォワーディング エン ジン(FE)で ELAM を実行します。L2 FE データ バス(DBUS)に、L2 およびレイヤ4 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL1941QX54 5 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6848-GE-TX SAL1825UZLA. The last day to order the affected product(s) is July 31, 2015. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6506-E, Catalyst 6509-E, Catalyst 6509-V-E, Catalyst 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles & Accessories. Switch Model : Cisco C6905-E. Power deniedPart Number Description 2 VS-S2T-10G= Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE withMSFC5 PFC4 2 S2TAIK9-15501SY Cisco CAT6000-VS-S2T IOS ADVANCED IP SERVICES FULL ENCRYPT 2 MEM-SUP2T-4GB 4G DRAM Memory Total for Sup2T and Sup2TXL (2G + 2G) - UPGR 2 MEM-C6K-CPTFL2GB Catalyst 6500 Compact Flash. 54 10. Bid 5221‐KO Cisco Equipment and Support LOT I Core CiscoVS-SUP2T-10G WS-X45-SUP7-E WS-X45-SUP8-E WS-X4640-CSFP-E WS-X4648-RJ45-E WS-X4648-RJ45V+E WS-X4748-UPOE+E WS-X6848-GE-TX. Table 2 Supervisor Engine 2T Models; Supervisor Engine 2T Product Numbers Description VS-S2T-10G The VS-S2T-10G is shipped with a factory-installed PFC4 daughter card (VS-F6K-PFC4) and a factory-installed MSFC5 daughter card (VS-F6K-MSFC5). Cisco annonce la date d’arrêt de commercialisation et de fin de vie de Cisco Catalyst 6506-E, Catalyst 6509-E, Catalyst 6509-V-E, Catalyst 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles and accessories. 4 Ok 7 Distributed Forwarding Card WS-F6K-DFC4-A SAL1927JC3V. %DOSFS-5-DIR_ENTRY_CORRUPTION: licdisk:1: has corrupted directory entries, Run fsck to get disk back to stable state If fsck failed to get the device back to stable state, Issue format on the device. Catalyst 6500 Sup2T; VS-S2T-10G-RF; VS-S2T-10G-RF. Catalyst 6509-E交換機:訪問產品規格、文檔、下載、Visio樣板、產品影象和社群內容。. Is the following upgrade process correct? 1. The entire process is pretty straight forward. below is the show inventory on my switch. After replacing it, load the same IOS as the old sup to the flash and than copy and paste the old config to the new sup from the console. Options. Could to create VSS with WS-X6816-10GE throughout etherchannels or only with the Supervisor Engine? And if is possible with two options what would be the difference? Attach the informations where say that is possible with supevisor VS-SUP2T-10G and card WS. Switching Modules. C6880-X-LE. Cisco Catalyst 6500-E Series Chassis Data Sheet ; 6800. 00. Options. 03-27-2012 01:46 AM - edited 03-07-2019 05:48 AM. 10-08-2019 08:17 AM. VS-S2T-10G VS-S2T-10G XL C6800-SUP6T C6800-SUP6T-XL You can also use these 40-GB modules with the Cisco FourX Converter Module 4: WS-X6904-40G-2T WS-X6904-40G-2TXL Cisco 10GBASE Dense Wavelength-Division Multiplexing SFP+ Modules Data Sheet. Catalyst 6506-E Switch: Access product specifications, documents, downloads, Visio stencils, product images, and community content. The Cisco Nexus 7000 Series Supervisor2 (Sup2) Module (Figure 3) is based on a quad-core Intel Xeon processor with 12 GB of memory and scales the control plane by harnessing the flexibility and power of the quad cores. 1SY OL-20679-01 Hierarchical List of Releases • See the “Hierarchical List of Releases” section on page 3 for information about parent releases. The two supervisor engines must match exactly. 3 4 CEF720 4 port 10-Gigabit Ethernet. EN US. Could someone verify if the IDSM2 is compatibility with the Sup2T (running s2t54-ipservicesk9-mz. Product Description. A Bridge Connecting IT Hardware to The World Routers Switches Firewalls Wireless Servers Storages Solutions Services About Us ×. Cisco announced some new modules for Cat6500 last month. 1ae with no additional latency. CSE NETWORKS. pdf - 4/12/2018 Cisco Catalyst 6500. (Don’t be confused by the fact that the old Supervisor 2 went end-of-sale on 2007. -VS-S2T-10G-XL= Cat 6500 Sup 2T with 2x10GbE and 3 x 1GbE with MSFC5 PFC4XL: C6800-SUP6T-XL= Catalyst 6800 Sup6T (440G/slot) with 8x10GE, 2x40GE (XL) MEM-SUP2T-4GB: 4G DRAM Memory Total for Sup2T and Sup2TXL (2G + 2G) -. Either two VS-SUP2T-10G or two VS-SUP2T-10G-XL supervisor engines. Replacement. VS-S2T-10G= Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE with MSFC5 PFC4 - VS-S720-10G-3C Cat 6500 Supervisor 720 with 2 ports 10GbE and MSFC3 PFC3C VS-S2T. They include a 48-port Gigabit Ethernet Copper Module and 48-port Gigabit Ethernet Fiber Module. 08-05-2012 07:57 PM. When your line card has the DFC4-A installed IT. The suggested release is 15. 18 191. Cat 6500 Supervisor 720 with 2 ports 10GbE MSFC3 PFC3C --Sweta *Rate and mark the helpful answers. Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 130°F (0° to 55°C) Humidity (RH) ambient (noncondensing) 10 to 90%. 87. 7 5 Supervisor Engine 2T 10GE w/ CTS (Hot) VS-SUP2T-10G SAL202801YG. We have VS-SUP2T-10G for sale, both refurbished and new, at prices typically up to 90% less than the original vendor price. 73 inches : Number of Processors 1 : Manufacturer CISCO : ASIN B005LFOUP0 : Is Discontinued By Manufacturer No :. Table 1. Labels: Labels: Catalyst 6000; LAN Switching; 0 Helpful Reply. 15 512. 5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G 6 5 Supervisor Engine 2T 10GE w/ CTS (Hot) VS-SUP2T-10G. 09-07-2021 03:08 AM - edited 09-07-2021 03:09 AM. Be aware that you have to also acquire a DFC4-A or DFC4-AXL which is a daughtercard of the line card. W/VS-F6K-PFC4 DAUGHTER CARD. The last day to order the affected product(s) is March 31, 2012. . This product is supported by Cisco, but is no longer being sold. Catalyst Chassis+Fan Tray + Sup2T; IP Services ONLY incl VSS-Product Migration Options. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Switch Accessories 03-Aug-2020. Supervisor Engine 2T integrates a high-performance 2-Terabit crossbar switch fabric that enables 80 Gbps switching capacity per slot on all. VS-C6513E-SUP2T. VS-SUP2T-10G Catalyst 6500 Supervisor Engine 2T Baseboard VS-F6K-PFC4 Cat 6k 80G Sys Daughter Board Sup2T PFC4 MEM-SUP2T-2GB Catalyst 6500. VS-SUP2T-10G Catalyst 6500 Supervisor Engine 2T Baseboard. . 24a2 to 1cdf. e. 18. Wanted to get netflow working and I. Aruba 8320 48p 10G SFP/SFP+ and 6p 40G QSFP+ Switch. the online version 15. The two supervisor engines must match exactly. 711: %DOSFS-5-DIR_ENTRY_CORRUPTION: licdisk:1: has. VS-10G is the multi functional smart VARILIMIT with various output options such as digital signal output, analog signal output, motion control and multi preset function. module 7 asic-1 temperature: 68C. 1. module 7 device-1 temperature: 40C. See more detailed modulesThe J9309A four-port SFP+ module only supports 10G transceivers. Refurbished VS-S2T-10G Supervisor Blade for Catalyst 6500 and 7600 Chassis Switches with Warranty X2 Modules shown in picture not included but available separately The Cisco® Catalyst® 6500 Supervisor Engine 2T is the newest addition to the family of supervisor engines. The two supervisor engines must match exactly. Modules:WS-X6908-10G ,WS-X6848-SFP,WS-X6908-10G ,WS-X6848-GE-TX , VS-SUP2T-10G . End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6506-E, Catalyst 6509-E, Catalyst 6509-V-E, Catalyst 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles & Accessories. Note The 1-Gigabit Ethernet ports and the 10-Gigabit Ethernet ports have the same QoS port architecture (2q4t/1p3q4t) unless you disable the 1-Gigabit Ethernet ports with the platform qos 10g-only global configuration command. 375: %C6KENV-2-DFCMISMATCH: Module 2 DFC incompatible >> with Supervisor DFC. Cisco Catalyst 6500系列Supervisor Engine 2、交换矩阵模块2 以及部分附件和软件版本终止销售 (EOS)和产品生命期终止 (EOL)声明 26-Aug-2016. The Gigabit Ethernet Copper Module supports RJ-45. module 7 device-2 temperature: 41C. C6807-XL-S2T-BUN. 5(1)SY1, page 53 † New. I have this problem too. The current switches have the same setup as per below: MUK_Core1#sh module. VS-C6509E-SUP2T. Little lost on which cards I should buy, or switch out the supervisor card. C6880-X-LE-SUP. e514. 70. vs-c6509ve-s72010g Catalyst Chassis+Fan Tray+Sup720-10G; IP Base ONLY incl. Find answers to your questions by entering keywords or phrases in the Search bar above. 879. That's because although your OP asked about a 6708, your installed card in a 6908. EOS/EOL for 64MB Compact Flash for Cisco Catalyst 6500. Read line card data sheet. This document is Cisco Public Information. module 7 asic-4 temperature: 64C. 1(2)SY2 OkEnd-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500/6500-E Series 1 Gigabit Ethernet Fiber and Copper Line Cards and Accessories 31-Oct-2016. White Paper © 2011 Cisco and/or its affiliates. The answer, I believe, is yes. The Future Is 40 Gigabit Ethernet White Paper (PDF - 2 MB) Virtual Private LAN Service on Cisco Catalyst 6500 Supervisor Engine 2T. Options. 75. module 7 asic-8 temperature: 70C. MSFC3. 1 Ok. 8aff 1. I have this problem too. Please help me to buy the supervisor engine of 6509 core switch and supervisor engine model no is vs-s2t-10g-2. Also, remember that this is just end of sales and Cisco will still support the existing cards for a few more years. Product Description. 423. There is two SUP2T-10G. Certified for operation: 0 to 6500 feet (0 to 2000 m) Working in conjunction with the Catalyst ® 6500-E/6807-XL Supervisor Engine 2T/2TXL (VS-S2T-10G & VS-S2T-10GXL), they can serve different needs on campus deployments. EOS/EOL for 64MB Compact Flash for Cisco Catalyst 6500. VS-S720-10G-3C= Cat 6500 Supervisor 720 with 2 x 10GbE and 3x1GE MSFC3 PFC3C-VS-C6513-S720-10G. 151-2. all non-XL or all XL. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Switch Accessories 03-Aug-2020. Define "long distances"? Are we talking about links on fibre? Can you post the complete output to the command "sh interface "?The Supervisor Engine 2T is designed to deliver higher performance, better scalability, and enhanced hardware-enabled features. We need to replace a VS-SUP2T-10G supervisor engine in a WS-C6509-E. 1. Beginner. Replacing bad 6807-xl vs-sup2t-10g mpkohan69. (Acti VS-SUP2T-10G SAL1618BM8W 2 16 CEF720 16 port 10GE WS-X6716-10GE SAL16159VEP 4 48 CEF720 48 port 10/100/1000mb Ethernet WS. Service prices for Cisco products are subject to change after the product End-of-Sale date. 29 percent or less . Mod MAC addresses Hw Fw Sw Status--- ----- ----- ----- ----- ----- 1 1cdf. 4 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6848-GE-TX SAL19038DU0. 001a to 503d. 07-14-2017 08:12 PM. make sure you unplug the VSL links made the changes then connect them again also update the config in the primary VSS switch and save the config before joining them over. The Cisco Catalyst 6500 Supervisor Engine 2T is designed to deliver higher performance, better scalability, and enhanced hardware-enabled features. 5 5 Supervisor Engine 2T 10GE w/ CTS (Active)VS-SUP2T-10G SAL15056BKR 对于Sup2T,在具有内部代号Eureka的第2层(L2)转发引擎(FE)上执行ELAM 操作 。 请注意,L2 FE数据总线(DBUS)包含L2和L3(L3)查找之前的原始报头信息,而结果总线(RBUS)包含L3和L2查找之后的结果。End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Switch Accessories 03-Aug-2020. The documentation set for this product strives to use bias-free language. 15. Below is a comprehensive. Tell me more about this line card: Was the line card sourced from a "used" seller? And did the owner disable password-recovery feature?Find many great new & used options and get the best deals for Cisco Catalyst 6500 Series Supervisor Engine VS-SUP2T-10G at the best online prices at eBay! Free shipping for many products!NEW OPEN SFP-10G-SR. (Acti VS-SUP2T-10G SAL1618BM8W 2 16 CEF720 16 port 10GE WS-X6716-10GE SAL16159VEP 4 48 CEF720 48 port 10/100/1000mb Ethernet WS. Operating temperature. 1 Ok 7 Centralized Forwarding Card WS-F6700-CFC SAL12372XVF. As per the cisco datasheet both the cards and the supervisor are compatible, just need to confirm this. WS-SUP720-3B Supervisor Engine 720 with PFC3B daughter card and. Product Overview. Skip to content. Catalyst 6503-E Switch: Access product specifications, documents, downloads, Visio stencils, product images, and community. 5(1) sy4, we run now on version 15. BTW, Reza mentions the sup and DFC XL feature needs to match, i. 50. We have no test 6500 to install the replacement supervisor engine to and put on the correct IOS and config in advance of the replacement. . With more than 83 Terabits per second (Tbps) of overall switching capacity, the Cisco Nexus 7700 Switches delivers the highest-capacity 10, 40, and 100 Gigabit Ethernet ports in the industry, with up to 768 native 10-Gbps ports, 384. 5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL15056BKR . And Cisco proposed the 2 substitutes written above: vs-s2t-10g= and vs-s2t-10g-xl=. I checked the supervisor and supports both tranceivers, but I want to know if I can have one of each instead of 2 of the same kind on the same supervisor. Labels: Labels: Other Switching; 0 Helpful Reply. Cisco 7606S Chassis,6-slot, VS-S2T-10G-XL,PS. the 6513-VS-SUP2T-10G supervisor engines do support VSS. VS. Either two VS-SUP2T-10G or two VS-SUP2T-10G-XL supervisor engines. Product Overview The Cisco ® Catalyst ® 6800 Supervisor Engine 6T (Figure 1) is the newest addition to the family of supervisor engines. 5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G 6 5 Supervisor Engine 2T 10GE w/ CTS (Hot) VS-SUP2T-10G . N/A. The high cpu usage by interrupts is the signal that many traffic flows are process switched in your C6509 instead of being processed by CEF. cat6000-rommon. Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE with MSFC5 PFC4 - WS-SUP720-3B . Please let me know the existing IOS is fine and provide the procedure to fix this issue. The 6708 line card is oversubscribed 2:1 so you'll never be able to get full 10GbE on all ports. VS-S2T-10G VS-S2T-10G XL C6800-SUP6T C6800-SUP6T-XL You can also use these 40-GB modules with the Cisco FourX Converter Module 4: WS-X6904-40G-2T WS-X6904-40G-2TXL Cisco 10GBASE Dense Wavelength-Division Multiplexing SFP+ Modules Data Sheet. the VS-SUP2T-10G. CISCO VS-S2T-10G, VS-SUP2T-10G,CMUCAB3BAA SUPERVISOR 2T WITH INTEGRATED SWITCH FABRIC/PFC4 AND 2 PORTS 10GBE. Only WS-X6904-40G-2T is being replaced and not the C6800-32P10G module. The forwarding engine on Supervisor. 15. 02. 41 x 1. we are planning to install C6800-8P10G= Interface Module on our WS-C6509-E (two switches configured on VSS). JL479A. The modules also work in Catalyst 6500 Series Switches. Open box. Beginner. 1SY releases: • Release 15. VS-SUP2T-10G*2,C6800-32P10G*2. 11-26-2018 09:12 AM. 2+ VSS mode support as shown in the Release Notes. can you please help me to choose the supervisor engine . Equipped with a high performance processor, the MSFC runs layer 2 protocols on one CPU and layer 3 protocols on the second CPU. Hi, We are trying to upgrade our 6807 VSS switches to 15. 86 VS-SUP2T-10G-MSFC5 Supervisor Engine 2T with MSFC5 daughter card. 5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL1642QKG9. Service Category. We are ready to help with your network equipment and services needs. Global Leader of Cybersecurity Solutions and Services | FortinetBeginner. 7Tbps. I was looking at the data sheet for the VS-S2T-10G and there was no compatibility mentioned with the WS-X6708-10GE module. Scott Fella. Hi, I have a VSS config with unequal number of switching modules as follows; Switch 1 ----- VS-SUP2T-10G (2x VSL) WS-X6704-10GE WS-X6748-GE-TX Switch 2 ----- VS-SUP2T-10G (2x VSL) WS-X6704-10GE Will VSS work if the WS-X6748-GE-TX isI need to upgrade a Cisco 6509 with dual SUP2T's from version 15. 2 Ok 3 Distributed Forwarding Card WS-F6K-DFC4-E xxx 1. MSFC3. VS-C6513E-SUP2T. VSS. 315. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center. Download the datasheet of Cisco VS-S2T-10G-XL.