Continually stay ahead of unpredictable customer demands with Ciena’s proven 6500 D/S-Series Packet Optical Platforms. Multiple configuration options with fully modular 4-slot or 10-slot chassis variants. Offers dual hot-swappable AC or DC power in a high-availability, temperature-hardened, 1RU package. 1G-111. MCP: Policy management for updating license server on network elements. Choose the Admin tab. of the 6500 to new levels of densities and scale, helping service providers address next generation web-scale requirements well into the future. 2 6500 RA logs can result in 6500 management issues. 6500. View full document. For detailed instructions regarding Site Manager Security and Administration, including a more detailed login procedure, see 6500 Packet-Optical Platform Administration. Change the directory by entering: cd /etc. terminal length 0 terminal width 512 show inventory raw show version show ethernet service instance detail show ip as-path-access-list show ip bgp neighbors show ip route static show ip route 0. OneControl : 8700 and 5170 nodes are constantly resyncing. We would like to show you a description here but the site won’t allow us. BIP. Ciena OME 6500 devices, OS version 10. Configuring an IS-IS Protocol Instance. Expand Post. Steps. 12. This includes 5400 NEs with embedded SONET/SDH services as well. Hi Vikash, the command I mentioned above is only related to 6500-PTS. I am currently using 100G QPSK. as “Foreign” or “Foreign Coherent”, and the associated CMD Tx/Rx adjacency. I need the User guide for the Waveserver Ai product not Waveserver. txt) or read book online for free. The 6500-D2 is a 2RU chassis composed of two service card-carrying slots enabling customized. Installation. Expand Post. Step 2: Select Photonic Services from the drop down menu. Preview. 1: If they don't match then continue to step-8. Using the MCP UI, select System > Configuration. 8700 Packetwave Platform data sheet. See Configuring the Route Recorder for instructions on defining SNMP. • Configuring the Route Recorder. Repeat on Site B (standby MCP) if one has been configured. ), Ciena 4200 series, Ciena 6500 and Ciena 8700 series. I also found a doc but for CPL and not 6500 : TID Consolidation Reconfiguration Procedure (Issue 1. Log in to Host 0 as bpadmin user and navigate to /opt/ciena/loads/7. of whatever Brocade sent (primitives, data frames, etc). g. . Click Edit at the bottom right of the page. Ciena 6500 | OTNStandalone License Server: 6500 Network Element fails to get license from License Server License Server: not able to add "Floating IP" onto a pair of LS in HA. The IP services browser lists all the EVPN & L3 VPN services. Then locate the product and SAOS version. Choose the MCP UI > System tab. Funcionality. The documentation set for this product strives to use bias-free language. It shows the mac. In the MCP UI, select System. . MCP presence of pre-5. ajay m (Customer) asked a question. x. Ciena 6500 Packet-Optical Platform 4x10G 2. With Ciena’s MCP domain controller as their foundation, MCP. 6500. never triggers an alarm in the 6500 just PMs. Collection of L2 interfaces using. Clear Procedure: Restore the connectivity between sites; specific corrective action will depend on the cause of the outage (e. Hi Ciena SME, we have two DWDM Ciena 6500 with follow configuration: CIENA 6500 Packet Optical Platform running software Releases 12. The compact, open, network edge platform is powered by. License Server: "Floating IP" onto a pair of LS in HA is not responding. Provides advanced Carrier Ethernet services powered by Ciena’s Service-Aware Operating System (SAOS) Supports two 100/1000Base-X SFP ports and a combo port supporting 100/1000 Base-X SFP and RJ-45 10/100/1000Base-T. The following is the sequence of steps performed for 6500 upgrade in MCP: Download 6500 software from to a file server. From 800G performance optics and 400G coherent pluggables to compact ROADMs and control plane automation, you can seamlessly maximize your investment from edge to core. 6500 Packet-Optical Platform. The 8700 is specifically optimized for 10GbE to 100GbE switching and aggregation, allowing you to deliver higher rate ports, services, and connections to meet market demands. Utilizes 1. BIP. Table 2. Expand Post. Installation Guide. 0 and there you find 430 pages of planning guide in PDF format (NTRN10EG. ISL port set to 8Gb to Ciena 6500 using standard Brocade shortwave SFP. 0 + Errata 20180314 [NDcPP] defines a. Configuring the Route Recorder. Service Delivery Switch. I was curious if others have seen this. Step 5: From the Trace Type drop-down menu, select the. Select Display Timezone. of whatever Brocade sent (primitives, data frames, etc). The 6500-T12/T24 shelves, operate with the robust and feature-rich 6500 software, and support high-density, high-capacity hardware modules. 49K views Top Rated Answers All Answers Amit G1 (Customer) 5 years ago Please use this link and under product documentation - ALL PRODUCTS 6500 PACKET-OPTICAL PLATFORM RELEASE 13. 2. Ciena® cannot be responsible for unauthorized use of equipment and will not make allowance or credit for unauthorized use or access. Private_IPV4_v1 (6500 specific policy, not supported in MCP 3. Step 2: Select Documentation. 43 and Transport Interface 4X10G OTR 4X XFP/4X SFP+ with Encryption, we need to know if these Ciena DWDM have compatibility to connect to SAN Cisco MDS 9706 Multilayer Director with. . Number of Views. a Layer 0 project has been committed in MCP. Step 3: Now from site manager , go to configuration tab ---> Equipment and facility provisioning and select the. Log into the MCP UI and select System > Configuration. Ciena is a global leader in optical and routing systems, services, and automation software. Schematics and illustrated parts list can also be included. Only 50% of all other 6500 nodes are available. 6500 Rel12. ) The Ciena 6500 Packet optical platform 2-Slot , 7-Slot ,14 Slot and 32 Slot Box is widely used . e. Upvote Upvoted Remove Upvote. The MCP provides the ability to enable/disable PM statistics on L3 VPN endpoints (VRF IP interfaces) at the time of their provisioning. Tongue, 2-Hole, Short Barrel w/Inspection Window, Brown, 2 AWG/35 mm2, 90-degree, #10 bolt holes on 5/8” center). The Cisco has a portchannel configuration in LACP which end's up in a Virtual Switch configuration in the Ciena 6500. Hello everyone! New here and trying to configure two 3916s for a demonstration. Allows a field replaceable module for distributed VNF hosting on an. Step 4: From the Shelf drop-down menu, select the required shelf. A configured VLAN interface can serve the same purposes as a physical interface, including serving as the selected administrative interface. Figure 2. @Note: Please make sure that third party network are transparent for GCC1 and GCC2. resourceTypes. Cisco compatibility matrix request to check this with DWDM vendor compatibility matrix and I don´t found at Cienna support portal the Ciena compatibility matrix with Cisco SAN Directors . When the IS-IS entry appears in the configuration hierarchy, click the arrow to its left to display the configuration interface. 93 nm to 196. Command. Z-Series: Node unresponsive in Planet Operate due to throttling errors and High CPU utilization. ) The Ciena 6500 Packet optical platform 2-Slot , 7-Slot ,14 Slot and 32 Slot Box is widely used . Name —Enter a name to identify the VLAN entry. Ciena Operational Commands. The display updates every 30 seconds. Going to Configuration>Nodal Connections and do not see 'photonic connection option. Bulk view of various device settings like NTP, RADIUS, License etc. 6500-T12 shelf equipped5171. Contacting Ciena For additional office locations and phone numbers, please visit the Ciena web site at Corporate Headquarters 410-694-5700 or 800-921-1144 Customer Technical Support. To consent to receive all cookies on all Ciena websites, click I acknowledge. The following topics for non-DOC-controlled systems: Topology Fundamentals Photonic Optical Control Photonic Applications Photonic Engineering Rules Photonic Set-Up Guidelines Provisioning Examples See Part 1 for the following. SITE-1 is directly connected to MCN (Management Communications Network) Shelf IP Address:. Command. Access the page here: Select Admin > Admin. MCP: Policy management for updating license server on network elements. Contacting Ciena For additional office locations and phone numbers, please visit the Ciena web site at Corporate Headquarters 410-694-5700 or 800-921-1144 Customer Technical. by Jojo Ferrer (Employee) 6500 Family. thanks in advance. EMC VPLEX Security Configuration Guide P/N 300-010-493 Rev A05 June 7, 2011 This guide provides an overview of VPLEX security configuration settings, including secure deployment and usage settings needed. Ciena’s 6500 Family of Packet-Optical Platforms enables you to stay ahead of unpredictable customer demands. This is a cheat list of the most used operational and troubleshooting Ciena Commands used in SAOS OS cli. BIT. I want to add new channels using Waveserver Ai using 100G/200G in 50GHz spacing. Step 2: Select Photonic Services from the drop down menu. x) When configured with SAOS software stream 10. The 6500 Reconfigurable Line System (RLS) is a compact, simple-to-deploy, photonic layer solution that improves scalability, reduces footprint, and offers more flexibility and programmability. S onver f w requir ore. Scroll down to your CMD44, it should be located in slot CMD44-1-83 or something similar. 6500 Packet-Optical Platform. OneControl : 8700 and 5170 nodes are constantly resyncing. Step 1: Click on the Configuration tab in Site Manager. Configuration without CKN key-string behavior change: Device# configure terminal. Expand Post. The 6500 offers integrated OTN and packet switching, for the based packet and OTN switching solutions; the configuration. The 6500 Family leverages Ciena’s Manage, Control and Plan (MCP) to provide end-to-end network and service lifecycle management across Ciena’sConfiguring the ROA. This acquisition doubled Ciena's size and increased its customer base to over 1000. A local or remote database backup can be performed using the command outlined in the RLS User Guide "Procedure 127", Backup and restore section. (There are guides for the 4200. Hi Ciena SME, we have two DWDM Ciena 6500 with follow configuration: CIENA 6500 Packet Optical Platform running software Releases 12. Take a database backup from the OME 6500. Topology Fundamentals 1-. Interop Issue Cisco 4500 - Ciena 6500. Steps. 22K how do I obtain proper console cable db-9 to rj-45 cable for the console. The branches in the tree are grouped under a top-level administrative domain, represented by a top-level folder icon on the web interface (shown as “Network” in the following figure). Step 5: Select the Shelf sub. We build the world’s most adaptive networks to address ever-increasing digital demands for richer. Offers ultra-low power per bit to reduce ongoing energy costs. This is a cheat list of the most used operational and troubleshooting Ciena Commands used in SAOS OS cli. Retrieve commissioning scripts summary for a heterogeneous project (6500, Waveserver and Waveserver5) Create the commissioning scripts to configure 6500 eMOTR cards; Enroll a Z-Series network element; View Z-Series inventory; Service provisioning after commissioning; Change a network element connection profile; Commission and. 4. Ciena Operational Commands. Basic Input/Output System. Ciena’s D-NFVI Software comprises three main components: • Ciena’s Base Virtualization OS includes an environment with kernel, user space, and application runtime framework, as required by the VNFs to be deployed. required port configuration setting for the Brocade to properly interact with the 6500. The following table lists the topics in this chapter. Select the date range for which the logs will be exported. Local authentication is always used as a fallback in the event that authentication through a remote. It enables 100GbE service delivery or 10GbE and 25GbE service. ROA supports routes mentioned in RFC 7432 in 20. Steps. September 28, 2020 at 3:44 PM. Allow Admin—Select to have this interface act. Navigate to System > Technical documentation > APIs > UAC. Mac hardware running OSx 10. Tech Touch Video: Live Chat Demo. Hi Paul, if what you are trying to do is start fresh, almost like a factory reset, then I believe the only way to do that is with a tool that only Ciena support engineers will have access to, so you would need to request that support. From there, you'll find 6500 related folders and can drill down based on release and more. 1. New in this release and documentation roadmap Installing 6500 14-slot shelves Installing OMX, fiber manager, DSM, passive equipment, and routing/connecting related cables. 1 provided basic NE management (a. For a 12AWG cable, there is the NTTC01EF variant. Funcionality. To reset the switch to factory default, issue the e rase startup-config or write erase command. It provides highly dense ROADM and amplifier configurations so you can quickly react to unpredictable traffic requirements by scaling nodal connectivity. pdf - Free download as PDF File (. Create a NE maintenance profile for the 6500 upgrade. x, the 3928 operates as an IP router supporting NETCONF/YANG to enable an open SDN environment with full visibility via telemetry and automated provisioning using open APIs. Ciena’s 8110 Coherent Aggregation Router is purpose-built for 100GbE services and aggregation. Guide for 6500 Alarm troubleshooting - Read online for free. 6_CLI)_Issue1. These attributes should not be edited unless: 1) a procedure in Ciena’s official product documentation directs the user to change a specific attribute, or 2) the user is advised by Ciena Technical Support or. A handful of 6500 OTN, packet, and hybrid packet/OTN interfaces support a wide range of protocols, allowing for rapid response to service requests and faster time to. Use the following procedure to configure MCP to auto-accept a new 6500 SSH key. Click Add, specify the values in the following figure and table, and click Save. The 3922 features a cost-effective 24 Gb/s switching fabric capacity, supporting two 1/10GbE and two 100M/1GbE fiber ports, and two 10M/100M/1GbE copper ports. The Catalyst 6000 series switches (Catalyst 6006 and Catalyst 6009 switches) are described in a separate publication, the Catalyst 6000 Series Switch Installation Guide. If you plan to use SNMP v2, enter the SNMP v2 community name. Broadband Inter-Carrier Interfaces; B-ISDN Inter-carrier Interface. Commissioning and Testing Release 12. x_Guide): 323-4001-100 - For All Configuration related stuff and general user guide6500 PACKET-OPTICAL PLATFORM RELEASE 13. Shelf Variants 6500-D7 Optical Type 2 6500-S8 Packet-Optical Power Options DC breakered/fused Max 50A 110/240V AC. The Ciena 6500 L0 CP implementation, similar to that of the 5400 and 6500. x or x. License Server: load license fails after Registered Server transferred from one account to another in Ciena Portal; Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. Once you're on Libraries, select the column header Name to filter the libraries alphabetically. For a zone to appear on the BGP Peering page in the web user interface, it must contain a BGP instance and a Traffic Recording. UCM6204_quick_installation_guide. From the Waveserver - 6500 interworking NTP: For more information on the Waveserver, including installation and system configuration, refer to the Waveserver User Guide,. A backup profile contains details of the backup process, backup transfer locations and number of backup files to be maintained for the NE. For further reference of 6500 " Lower layer GCC implementation rules" please refer to this handbook 6500 Packet-Optical Platform Planning, Part 4 of 4, (NTRN10DB). MCP Documentation. The 6500 S-Series shelf configurations are equipped with an agnostic, centralized packet/OTN switched fabric, scaling from 600Gb/s to 3. . Hi Vikash, the command I mentioned above is only related to 6500-PTS. This guide describes the hardware features of the Catalyst 6500 switch. Tailored to address enterprise business requirements at the edge, the 6500-D2 Packet-Optical Platform is a compact 2RU chassis that cost-effectively extends the flexibility and resiliency of the 6500 platform from the core to the access. BIOS. 5. Step 3: In the Product Documentation tab, find and select the applicable product (ie. For more details on the command line, please refer to "323-1851-193_(6500_R12. Supports 2 GbE NNI/UNI Small Form-factor Pluggable (SFP) ports. a) Go to Configuration-->Comms Settings Management-->Interfaces--> Select the shelf-->Select LAN in Interface Type tab-->Then select the alarmed ILAN port and compare configuration parameters. The display updates every 30 seconds. Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. This is how all console connections are connected in lab. 6500-D14/S14 Packet-Optical Platform. We are covering Ciena 3900 series (3902, 3916, 3920, 3930, 3940, 3960, etc. To update on demand, click Refresh . Table 1. 0, Firmware Version: 1. ), Ciena 4200 series, Ciena 6500 and Ciena 8700 series. Step 2: Select Documentation. Ciena’s 6500 Family of Packet-Optical Platforms enables you to stay ahead of unpredictable customer. For a zone to appear on the BGP Peering page in the web user interface, it must contain a BGP instance and a Traffic Recording. BIT. Performance monitoring. 255 longer-prefixes show ip route connected show. 18. Ciena® cannot be responsible for unauthorized use of equipment and will not make allowance or credit for unauthorized use or access. SP w/access panel (SPAP) SP w/access panel (SPAP-2) w/2xOSC 2xSFP. ONID. . A TAPI node can exist on different abstraction levels in the network and map to a single device or a collection of devices. Memory: 8 GB 1333 MHz. IP transport page is displayed. 2 card-based packet/OTN switching hardware is available for. 0 Product 6110 6130 6150 6500 Optical Metro 3100 Optical Metro 3400. From the side menu, choose Geolocation Setup/Configuration. Bias-Free Language. 43 and Transport Interface 4X10G OTR 4X XFP/4X SFP+ with Encryption, we need to know if these Ciena DWDM have compatibility to connect to SAN Cisco MDS 9706 Multilayer Director with. Hello Huy, you can check the software status on this node in Release Management under configuration. Step 4: Select the row of the required shelf from the Node Information table. We are using WLAi FOTR modules for the path. Command strings; Prompts and responses from the systemHi Diego, 6500 needs to be operated within the mentioned Environment guidelines in the planning guide . The Edit configuration setting dialog box displays. Ciena6500. Step 7. The collaborative Protection Profile for Network Devices, version 2. The 6500 Family comes in multiple chassis form factors, from a compact 2RU, up to full rack sizes, with the ability to scale from 100 Gb/s to 500 Gb/s per. x. Note as well that for eMOTR and PKT fabric, the 6500 only supports SNMPv3 as the 6500 SP uses an SNMPv3 proxy for eMOTR and PKT fabric. 4. Number of Views 590. Common items between sites: 6500 7-Slot Type 2 Optical. Data sheet Watch video. September 28, 2020 at 3:44 PM. 1 . Z-Series: Node unresponsive in Planet Operate due to throttling errors and High CPU utilization. I have a 6500. Local authentication is always used as a fallback in the event that authentication through a remote. these benefits across 6500 hardware that supports compact WaveLogic 5 Nano 100G/200G CFP2-DCO pluggables. In the Add or Edit Peers window, click New and enter the IP Address or Prefix of the router. 6 Tb/s. Command to issue to save the running config to memory. Via the Live Support Chat button on Support page. ONID. Kevin Mizerek (Ciena. 0SY 38 Virtual Private LAN Services (VPLS) • Prerequisites for VPLS, page 38-1 † Restrictions for VPLS, page 38-2 † Information About VPLS, page 38-2 † Default Settings for VPLS, page 38-6 † How to Configure VPLS, page 38-6 † Configuration Examples for VPLS, page 38-18. If you are using Site Manager, in the Edit/Preferences, you can set the TIme Zone display from NE to Local OS / PC. Path tab is usually the default selection. Ciena’s 3948 is a cost-effective router designed to address the requirements for higher capacity and end-to-end disaggregated IP services at the network access, supporting 4G network evolution, 5G deployments, enterprises, and next-generation business services. these benefits across 6500 hardware that supports compact WaveLogic 5 Nano 100G/200G CFP2-DCO pluggables. Using the MCP UI, select Network > IP transport. Click the Path tab. Site Manager hardware requirements; Site Manager port requirementsExcerpt from the Photonic Layer Guide, part 1 (NTRN15DA) In the Site Manager Configuration -> Equipment/Facility Provisioning screen, the Tx/Rx adjacency of the 6500 CMD port must be edited to the type labeled. 0_Planning)_Issue1) Expand Post. 9. Overview; Required files; Required users; Prerequisites. mac show. conf logrotate_original. on your website. VPWS indicates that this is a Virtual Private Wire Service. The MCP system comes preconfigured with the admin user that is assigned all default roles automatically: Application admin: administration of MCP, application-level security, basic visibility of network elements and services. Offers 82 Gb/s of non-blocking switching capacity in a compact service demarcation device, running Ciena’s SAOS for advanced OAM and QoS functions. (!!)Check the upgrade state of all the circuit packs from Site Manager or check the software version and clear. Adaptive IP Guide. Make sure the FTP port on the computer is unblocked. 3. the SLAT tool is the best way to set up a shelf from what I remember, maybe you can try just finishing the set up with that,. On the Ciena Portal - Support / Documentation. This Security Policy describes how the Ciena 6500 Packet-Optical Platform 4x10G meets the security requirements of at the edge, the 6500-D2 Packet-Optical Platform is a compact 2RU chassis that cost-effectively extends the flexibility and resiliency of the 6500 platform from the core to the access. Converged Packet Optical 6500 Family OME 6500 : SFP specification sheet 6 July 2021, Version 2 Issue/Question OME 6500 : SFP specification sheet Environment. f Resolution: - (!) Identify the pluggable module raising the alarm. It describes the physical and performance characteristics of the switch, explains how to install a switch, and provides troubleshooting information. . Select Adaptive IP administration > Admin > VNC Configuration. set ciena-6500r-system:system id member [name <string>] Step 3: Logout and log back in to the shelf to confirm if the system name got updated. Choosing a Ciena OME 6500-D2 will increase your network support on the Ciena OME 6500-D7/S8 configuration allowing you to bridge the ethernet, WDM and TDM rack configurations providing the capacity to meet web-scale demand, as well as Ciena's 6500 Optical Platform Converges package, optical transportFor 6500 Photonics OTS link (Fibre) and OMS link (ROADMLine), there are a few rules governing the total capacity: A maximum C-band allocation is 191. MCP provides a list of configurable parameters that are used for allocating SIDs. Network admin: full control of network elements and services. Link: A Link represent the unterminated transfer of. Table 1. 6500 Troubleshooting Guide P a g e 13 | 17 11. 3806 XGS-PON Weatherproof Optical Network Unit. Ciena Commands. With the ability to provide on-demand connectivity and terabit switching, you can continually stay ahead of unpredictable customer demands with Ciena’s 6500 T-Series Packet Optical Platforms. 2Tb/s of switching. Steps. 6500-S32 packet/OTN switched configuration with integrated three-way ROADM . The "Create configuration setting" dialog displays. the config guide for 6500. SLAT process overview Nodal SLAT procedures Photonic layer provisioning procedures Photonic layer site testing procedures Fixed-plan terminal node procedures Passive OTS network procedures Wavelength addition and deletion Appendix A:. Incorporates on-board RFC 2544 Performance Benchmark. Failure Analysis Configuration. Click Edit. 74K. Network Element should not be allocated with any SID value. 16 Sep 2015. rdp; Driver Tier: 1; Vendor: Ciena. Table A-3 950 W AC-Input Power Supply Specifications . Step 1: If a new database backup is required to be generated, execute the following command in CLI: database-backup <filename>Using a Phillips screwdriver, secure the module in place using the captive hold down screw on the right of the module. 8 Tb/s—just what you need to gain a competitive advantage as the dynamics of metro and regional networks shift. MCP presence of pre-5. - documentation identifier (0000). Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. Security Configuration Guide, Cisco IOS XE Fuji 16. 1 and 10. The Catalyst 6000 series switches (Catalyst 6006 and Catalyst 6009 switches) are described in a separate publication, the Catalyst 6000 Series Switch Installation Guide. The 6500-D2 is a 2RU chassis composed of two service card-carrying slots. 32500 THz/1566. Note: The procedure number may change depending upon the Release, but the document 323-1851-320 will be the. The configuration hierarchy organizes components in a tree structure, with each branch representing a different part of the configuration. 6500-D14/S14 6500 Packet-Optical Platform. Integrates line-rate Service Activation Testing capabilities. 7) The 6500 Reconfigurable Line System (RLS) is a compact, simple-to-deploy, photonic layer solution that improves scalability, reduces footprint, and offers more flexibility and programmability. Step 1: First make sure that Optical link in between CIENA to CIENA port is up through third party network. MCP Documentation. Then locate the product and SAOS version. ISL port set to 8Gb to Ciena 6500 using standard Brocade shortwave SFP. . required port configuration setting for the Brocade to properly interact with the 6500. This command does not clear the boot variables, such as config-register and boot system settings. Low footprint 1RU in a nonblocking architecture with: - 6 x 1GbE/10GbE SFP+ ports - 2 x 100M/1GbE ports. Step 5:. The question is if the 6500 Ciena DWDM listed has been tested with Cisco 9706 MDS SAN Director and firmware NX-OS 8. Step 2: There should be any alarm on these ports. ) Any help is. In the BGP Peers section, click Configure Peers. Supports 4 GbE NNI/UNI ports including 2 100/1000 Base-X SFP ports and 2 dual-mode ports: RJ-45 10/100/1000 Base-T and 100/1000 Base-X SFPs. You can use the Market REST API to assign a node role on a device for the first three steps in the process and the Network element (constructs) REST API for the fourth and final step in the. Using the MCP UI, select System > Configuration. Number of Views 2. g. Supports zero-touch provisioning to minimize OPEX and accelerate service turn-up while providing a. Additionally, the cost-effectiveness and versatility. Does 6500 PTS(NTK614AA/fabric and Ntk695aa/interface) support 2. Select displayTimezone. Z-Series: Node unresponsive in Planet Operate due to throttling errors and High CPU utilization. Select the application “raciena6500” with the name "Auto accept new SSH Key". 6500 T-Series. Create a copy of the logrotate. x: Manual CTX switchover causes all LM modules to reboot; MCP - All license servers within the Primary site are UNREACHABLE; 6500 RLS License Violation and External License Server Comms Failed; Standalone License Server Unable to load. From the Ciena Virtual Assistant (bottom-right) under “Get Support -> Technical Support -> Live Support Chat. Choosing a Ciena OME 6500-D2 will increase your network support on the Ciena OME 6500-D7/S8 configuration allowing you to bridge the ethernet, WDM and TDM rack configurations providing the capacity to meet web-scale demand, as well as Ciena's 6500 Optical Platform Converges package, optical transport For 6500 Photonics OTS link (Fibre) and OMS link (ROADMLine), there are a few rules governing the total capacity: A maximum C-band allocation is 191. Enter the name in the Name field exactly as it appears in the 'Key and Name' column in the preceding table. Page 72 At the DC input circuit, restore power to the DC circuit. What’s inside. x states Ciena has passed responsibility for providing the. 24/7 in-flight data protection with wire-speed encryption As part of Ciena’s multi-layer security approach that ensures the confidentiality, integrity, and availability of data in the network, the 6500 offers advanced integrated AES-256Course Description. The Performance Metrics or Performance Monitoring (PM) microservice orchestrates the collection of metrics from resources. Funcionality. It starts at 800 Gb/s and scales to a massive 6.